At a glance
A seven-patient colorectal cancer study found a 500-gene panel matched itself across blood and tissue, but shared only two top genes with whole-exome sequencing.
Only two genes appeared on both lists. Sequence a colorectal tumor with a targeted 500-gene panel, sequence the same tumor again with whole-exome sequencing, and the two methods rank the tumor's most frequently mutated genes almost completely differently — at least across the seven patients compared in a 2022 American Association for Cancer Research (AACR) abstract co-authored by Roman Alpatov.
The two genes were APC and TP53.
Hospitals order these tests now to decide who gets which drug, and the answer can turn on which genes a panel was built to read. A 500-gene panel isn't a cheaper version of whole-exome sequencing. It's a different instrument, aimed at a different question, and the oncologists reading its output are reading the result of a design choice made years earlier.
Most of the rest of the abstract is friendlier to the panel. Illumina's TruSight Oncology 500 (TSO500) can read DNA from a stored tissue block or from blood plasma, and its two versions agreed closely with each other: 19 of the 20 most frequently mutated genes were identical whether the DNA came from tumor tissue or from a blood draw, and 889 variants — 56.9% of everything the panel called — appeared in both. A blood test that recovers most of what a biopsy shows is the entire commercial premise of liquid biopsy.
Whole-exome sequencing, run on the same tissue, did not confirm that picture. So which report describes the tumor?
What the seven patients actually had done
The study, presented at the AACR annual meeting and published as abstract 5105 in Cancer Research, took matched tissue and plasma from seven patients with stage III or IV colorectal cancer who had not yet started treatment. Each tissue sample was sequenced twice — once by whole-exome sequencing (WES), once by the TSO500 tissue panel. Cell-free DNA extracted from each patient's plasma went through the TSO500 ctDNA panel. Three assays per patient, two sample types.
Variant calls were filtered to protein-altering changes: frameshift, in-frame, nonsense, missense, translation start site, nonstop and splice site variants. Genes the exome found mutated were then checked against what the panel reported, and the R package maftools was used to work out which genes were hit most often in each dataset.
The analogy that fits: the panel is a street-level photograph of roughly 500 buildings, taken at high magnification with plenty of light. The exome is a satellite image of the whole city at lower resolution. Both are pictures of the same place. Neither substitutes for the other, and a difference between them isn't automatically an error.
The numbers behind the concordance claim
In plasma, the panel called 1,300 variants and 33 copy-number variants. In tissue, it called 1,199 variants, nine genes with high-level copy-number changes and three gene fusions. Those 889 shared variants mean roughly 400 were seen only in blood and about 300 only in tissue.
The correlations the authors report are high: 0.81 between the panel's tissue and plasma results, 0.91 between WES and the panel on tissue, 0.84 between WES and the panel on plasma. Those are r² values, squared correlation coefficients that run from 0 to 1, where 1 means two sets of measurements move in perfect lockstep. They describe how closely the variant totals tracked each other across the seven samples. They don't say whether any individual mutation was called at the same allele fraction by both methods.
Two of the comparisons rest on small numbers, and the abstract is explicit about it: the WES-versus-panel tissue figure is based on 47 variants, and the WES-versus-plasma figure on 17. The abstract is indexed in Cancer Research with the meeting supplement.
FAT1 tops a list that APC and TP53 usually own
"Most commonly mutated" is a fragile title in a cohort of seven. It can mean a gene was altered in three patients.
FAT1 led both panel datasets, tissue and plasma. That is an unusual result. APC and TP53 are the standard leaders in colorectal cancer; FAT1, a cadherin-family gene sitting on chromosome 4q35, is altered in a minority of tumors. A 2013 study in Nature Genetics found FAT1 mutations in 7.7% of colorectal cancers and showed the protein suppresses cell growth by binding beta-catenin and keeping it out of the nucleus. A later survey of 526 colorectal tumors from The Cancer Genome Atlas put FAT1 mutation frequency at 10.5%.
In a group of seven, a gene altered in roughly one tumor in ten can climb to the top of a frequency table by chance. That doesn't make the observation wrong. It makes it a hypothesis the fuller analysis would need to test.
The same caution applies to the headline gap. If a gene is genuinely among the most frequently mutated in a tumor and simply isn't on the panel, the panel's silence is a design limit rather than a miss. Comparing top-20 lists across two assays is comparing two sampling frames.
Photo by National Cancer Institute on Unsplash
The pathway that ran away with it
Across both panel datasets, the RTK-RAS pathway carried mutations in 22 genes — by far the most of any pathway the authors examined. RTK-RAS is the signaling route that anti-EGFR antibodies such as cetuximab and panitumumab act on in colorectal cancer, and the presence of a RAS mutation is a standard reason not to use them. The abstract does not connect its pathway result to treatment decisions, and it shouldn't be read that way. But a panel whose job includes answering "could this patient get an EGFR inhibitor" will spend a large share of its reads on exactly this stretch of the genome.
What seven patients can and can't show
Every patient in the cohort had stage III or IV disease and none had started treatment, which is the cleanest setting for a methods comparison and the least representative of a real clinic, where samples are older, smaller and often taken after several lines of therapy. There were no outcomes. There was one timepoint. And an abstract is a poster summary, not a peer-reviewed paper, so the analysis behind the correlations hasn't been through full review.
A bioinformatician would add a second objection: 56.9% variant overlap counts shared calls, not shared measurements. Two assays can both report a mutation while disagreeing about its allele fraction, its confidence score or whether it sits in a subclone. None of that shows up in an overlap percentage.
Seven patients also can't settle whether a panel is better or worse than an exome. That isn't the question the study was designed to answer.
Who paid, and what the abstract doesn't say
EMD Serono Research and Development Institute in Billerica, Massachusetts, and Merck KGaA in Darmstadt, Germany, are the two affiliations printed on it. Both companies develop oncology drugs and the biomarker tests that accompany them. A result showing that a commercial panel reproduces most of a blood biopsy's findings, and tracks well against exome sequencing, is a result those companies can use.
No funding statement appears in the abstract. No conflict-of-interest disclosure either. Abstracts of this kind often omit both, and the omission is a gap: readers can't see who paid for the sequencing, whether the assay's manufacturer supplied reagents, or what the authors' commercial relationships are. The data may be perfectly sound. The transparency is incomplete.
Labs elsewhere are already running this experiment
A 2023 analysis using Illumina's cell-free ctTSO500 assay across 124 cases of colon, gastric, uterine, lung, prostate and other cancers listed the O'Rourke and Alpatov work among four studies used to set expectations for plasma-to-tissue concordance. In colon cancer, that analysis found 47% of the single-nucleotide variants and insertions or deletions detected in plasma were also present in the matching formalin-fixed tissue, a figure in the same neighbourhood as the 56.9% reported in the colorectal abstract. The comparison is published in the Journal for ImmunoTherapy of Cancer.
The IMPRESS-Norway trial, a national precision-oncology study, ran matched tissue and ctDNA profiling on 615 patients with advanced cancer and put the results in front of a molecular tumor board. Actionable biomarkers were concordant in 48% of cases, found in tissue only in 43%, and found in ctDNA only in 8%. The pattern is consistent: liquid biopsy adds information and misses information, roughly in that proportion, and tissue remains the reference point for patients who can still provide it.
For the patient, the practical consequence is blunt. A negative blood result in colorectal cancer does not rule out an actionable mutation, because a tumor that doesn't shed DNA into plasma gives the assay nothing to find. A positive blood result still usually gets confirmed on tissue when tissue is available.
Photo by National Cancer Institute on Unsplash
What to watch
The authors close by noting that a deeper analytical dive into each dataset is ongoing. That follow-up is where the useful questions sit: whether the panel and the exome agree variant by variant once allele frequency is folded in, whether the plasma signal tracks tumor burden over time in the same seven people, whether payers will ever accept a plasma-only report when no block can be retrieved, and whether anyone can show that a therapy chosen from a panel result works better than one chosen from an exome result.
If tumor-informed ctDNA monitoring becomes routine for detecting colorectal cancer recurrence over the next decade, the sequencing method underneath each result will have to be chosen deliberately rather than inherited. That's what this small comparison puts on the table, and why it keeps turning up in reference lists four years after a poster session in Philadelphia.
- precision-oncology
- colorectal-cancer
- cancer-genomics
- liquid-biopsy