Academic Jobs - Home of Higher Ed Logo

Hot Chai, Cold Water: Hina Hammad Tests Whether Smart Dental Fillings Hold Their Seal

10 min read8 views

At a glance

Hina Hammad's bench study of 80 extracted premolars finds repeated hot and cold exposure drives microleakage around dental fillings, with Activa BioACTIVE showing the lowest mean leakage of four materials tested.

dental exam with mirror and tool
Photo by Caroline LM on Unsplash

Two cups of chai, one glass of ice water, and a filling that has to hold its edge against both. That is roughly the test Hina Hammad built in a dental materials lab in Karachi, and the results put a number on something patients feel but rarely hear explained: the seal around a tooth-coloured filling doesn't wear out so much as it gets worked loose, cycle by cycle.

Hammad, an assistant professor of operative dentistry at Hamdard University Dental Hospital, led a team that restored eighty extracted human premolars with four different materials and then drove them through 1,500 temperature swings between 5°C and 55°C. Teeth that alternated between the two extremes leaked about two and a half times as much dye as teeth that were never heated or chilled at all, measured on a 0–3 penetration scale. The alternating group averaged 1.85; the untouched controls averaged 0.75. The findings appear in the Indo-American Journal of Life Sciences and Biotechnology.

The timing matters because the materials in the study are the ones dentists are being sold hardest right now. Activa BioACTIVE, Cention N and EQUIA Forte HT all belong to the loosely defined family of “smart” or bioactive restoratives — materials designed to release fluoride, calcium and phosphate ions, buffer acid, and in some cases form a mineral layer at the tooth-material junction. Manufacturers lean on that chemistry in their marketing. Independent data on whether the chemistry survives a decade of coffee and ice cream has been thin, and much of what exists comes from short laboratory runs using different protocols that are hard to compare.

Hammad's study puts a plain nanohybrid composite — the workhorse resin most patients already have in their mouths — into the same test alongside the three newcomers. That comparison is the part clinicians will read first.

The gap you can't see, and why heat opens it

Microleakage is the seepage of bacteria, fluids and dissolved molecules through the microscopic space where a filling meets tooth. No direct restoration bonds perfectly. Both materials and tooth shift with temperature, but they shift by different amounts, because every material has its own coefficient of thermal expansion — a measure of how much it grows per degree of warming. Enamel and dentine move one way; a resin composite moves another. Picture a metal lid screwed onto a glass jar. Run hot water over the pair and the lid loosens, not because either part changed shape, but because they changed shape at different rates.

In a tooth the gap that opens is measured in micrometres. It closes again on cooling, but not always perfectly, and the repeated open-shut action is what the lab test is designed to stress. Over years, that pumping motion can pull in dye, acid and bacteria, which is the pathway to secondary decay under a filling that still looks fine from the outside.

Thermocycling machines automate the abuse. Hammad's device held water at 5°C in one bath and 55°C in another, dunked each restored tooth for 30 seconds at a time, and repeated the sequence 1,500 times.

How the experiment was assembled

Eighty sound premolars, extracted for orthodontic reasons, were mounted in acrylic resin. Each received a standardised Class V cavity — the wedge-shaped lesion that forms at the gum line on the cheek side of a tooth — cut to 4 millimetres mesiodistally, 2 millimetres occlusogingivally and 2 millimetres deep, with the gingival margin sitting in dentine or cementum and the occlusal margin in enamel. That margin placement is deliberate and clinically realistic: bonding to enamel is far more forgiving than bonding to dentine.

Twenty teeth went to each material. Light-cured materials got 40 seconds of curing. Each material group was then split into sub-groups exposed to heat alone, cold alone, alternating heat and cold, or nothing at all — a non-thermocycled control that shows how much leakage each material produces before any temperature challenge. After cycling, the teeth were soaked in methylene blue dye for 24 hours and sectioned, and the depth of dye penetration along the cavity walls was scored under a stereomicroscope.

MaterialClassMean microleakage score (0–3) with standard deviation
Activa BioACTIVEBioactive ionic resin-based restorative0.85 ± 0.67
Cention NAlkasite1.10 ± 0.72
EQUIA Forte HTGlass-hybrid ionomer1.25 ± 0.79
Conventional nanohybrid compositeResin composite (control material)1.65 ± 0.88

Differences between materials were statistically significant at p ≤ 0.05, as were differences between temperature conditions. Hammad's discussion attributes the spread to “differences in the chemistry and physics of the constituents.” The EQUIA result is linked in the paper to its glass-hybrid composition and the resin surface coating applied after placement, which is designed to protect the material during its early, vulnerable setting phase.

The surprise isn't which filling won. It's when the ranking appears at all

Under a single steady temperature — hot only, or cold only — the four materials could not be reliably told apart. No significant differences in mean microleakage emerged among them. The conventional composite was not worse than the bioactive materials when the thermostat stayed put.

The ranking only separated once the teeth were forced to swing back and forth. That is the finding with practical weight. It means a study that tests a material at one temperature, or that cycles too gently, can conclude that material chemistry hardly matters. Hammad's data suggest the opposite: chemistry matters specifically at the moment a filling is being asked to expand and contract in alternation, which is what happens over the course of a normal meal with a hot drink and something cold afterwards.

By condition, the alternating hot-cold group averaged 1.85 (standard deviation 0.79), cold alone 1.18 (0.74), hot alone 1.05 (0.68), and the uncycled control 0.75 (0.55). In that hardest alternating condition, Activa BioACTIVE and EQUIA Forte HT held up better than the other two materials, which is why the paper's conclusion names both as showing the greatest resistance to food- and beverage-induced temperature change.

The plausible mechanism for a bioactive resin is ionic. Activa formulations contain reactive glass fillers and an ionic resin matrix that takes up water and exchanges calcium, phosphate and fluoride with saliva, which can deposit mineral at the interface and narrow small gaps. Whether that mechanism is what produced the lower dye scores here wasn't directly measured — the study tracked leakage, not ion release. Hammad's paper is careful on the point, describing the low Activa reading as possibly due to the bioactive resin formulation and its interaction with tooth structure rather than asserting a proven cause.

What the study cannot tell you

It's a bench experiment on extracted teeth, and the authors say so plainly, calling for further work on food and beverage temperature change and other clinical conditions before the long-term behaviour of these materials can be judged.

The specific gaps are worth spelling out, because they cut in different directions. Teeth in the study were sound premolars; the caries-affected and sclerotic dentine dentists actually meet in clinic bonds less predictably. The specimens endured no chewing load, no salivary enzymes, no bacterial biofilm and no acidic drink challenge, all of which act on a restoration at the same time as temperature. Methylene blue is a small molecule and will find its way into gaps too narrow for a bacterium to pass, so dye studies tend to overstate the clinical risk implied by their numbers.

Then there is the cycling itself. Hammad's protocol ran 1,500 cycles. That is a reasonable simulation of a few years of eating, but other laboratories have pushed far harder — 5,000 cycles, 10,000, even 50,000 in studies intended to represent five years of service. Rankings can shift when the stress is extended.

They already have. A thermocycling study of the same three novel materials published in the International Dental Journal put EQUIA Forte ahead of both Activa BioACTIVE and Cention N after 5,000 cycles between 5°C and 55°C. A 2026 micro-CT study in Scientific Reports modelling one year and five years of ageing found the reverse pattern for the glass-hybrid: EQUIA Forte HT's sealed volume deteriorated significantly over the longer simulated period, while Cention N and Activa BioACTIVE showed no significant increase in leakage. That study also found both bioactive resins on par with its conventional composite control — a direct contradiction of Hammad's finding that the nanohybrid performed worst.

None of these results is necessarily wrong. Different cavity preparations, adhesives, curing lights, cycle counts and dye or tracer methods will produce different orderings, and a single lab study is one data point. What the disagreement establishes is that no material in this class has yet been shown to be reliably superior across protocols. Anyone quoting one paper as proof that a specific filling lasts longer is overreading it.

What it means for the person in the chair

For a patient holding a treatment plan, the most useful takeaway is not a brand name. It's the recognition that the weak point of a filling is the seam, that the seam is stressed by temperature change rather than by steady heat, and that the stress accumulates invisibly. A filling that fails usually does so from underneath, which is why dentists probe margins and take bitewing radiographs at recall appointments instead of trusting appearance.

For the clinician choosing stock, Hammad's numbers give a defensible reason to reserve the more technique-sensitive resin composites for situations where their aesthetics or strength are decisive, and to weigh ion-releasing materials more heavily for cervical and gum-line restorations in patients who drink a lot of very hot or very cold liquids. That is a judgement call the paper supports at the level of a trend, not a prescription.

There is also a quieter point about how dental materials are evaluated. Most published leakage studies use one thermocycling recipe, chosen by the authors, and often only report whether a material leaked more or less than a rival. Hammad's design — a never-cycled control for every material, plus separated hot, cold and alternating arms — is what made the temperature-dependence visible at all. That structure is cheap to copy and would make the literature easier to compare.

The full study, “Influence of Simulated Hot and Cold Dietary Temperatures on the Microleakage Resistance of Smart Dental Restorative Materials,” is published in the Indo-American Journal of Life Sciences and Biotechnology and available through its DOI record. Earlier work from related groups on how bioactive restoratives behave at the cavity margin, including a 2024 comparison of Activa formulations against nanohybrid composite, points in a similar direction: the ion-exchange chemistry does something at the interface, but how much it does depends heavily on the test.

Where this line of work goes next

The obvious next experiment is the one the paper asks for: thermomechanical cycling that adds chewing force to the temperature swings, run on caries-affected dentine rather than pristine premolars, with ion release measured alongside leakage so the mechanism can be tested instead of inferred. Prospective clinical trials comparing these materials in gum-line restorations would settle what bench studies cannot.

Within five to ten years, the more interesting shift may be in how restoratives are designed. If a material can be engineered so its thermal expansion sits closer to that of enamel and dentine, the pumping action at the margin shrinks at the source rather than being patched with mineral deposition. Several research groups are already working on filler systems and resin matrices tuned for exactly that mismatch. Hammad's contribution is to show, with a clean four-arm design, that the mismatch is where the difference between materials actually shows up — and that a filling tested only in still water tells you very little about the one in a mouth that drinks its coffee hot.

  • dental-microleakage
  • smart-dental-restorative-materials
  • activa-bioactive
  • operative-dentistry
  • thermocycling
Portrait of Jarrod Kanizay
About the author

Jarrod KanizayView author

Academic Jobs In House Author

Visionary leader transforming academic recruitment with 20+ years in higher education.

Discussion

Sort by:

Be the first to comment on this article!

You

You’ll be asked to sign in before your comment is posted.

Browse by Faculty

Browse by Subject

Frequently Asked Questions

🦷What is microleakage in a dental filling?

Microleakage is the seepage of bacteria, fluids, ions and molecules through the microscopic gap where a restoration meets tooth structure. No direct filling bonds perfectly, and the interface opens slightly when the material and the tooth expand or contract at different rates during temperature change. Over time that pumping action can admit acid and bacteria and lead to decay beneath a filling that still looks intact.

🌡️What did Hina Hammad's study actually measure?

The team restored 80 extracted human premolars with standardised Class V cavities at the gum line and exposed them to 1,500 cycles between 5°C and 55°C in a thermocycling device, with a 30-second dwell at each temperature. Teeth were then soaked in methylene blue dye for 24 hours, sectioned, and scored under a stereomicroscope for how far the dye had travelled along the cavity walls.

🔬Which filling material performed best in the study?

Activa BioACTIVE produced the lowest mean microleakage score at 0.85, followed by Cention N at 1.10, EQUIA Forte HT at 1.25, and the conventional nanohybrid composite at 1.65. The differences between materials were statistically significant. In the hardest alternating hot-cold condition, the paper singles out Activa BioACTIVE and EQUIA Forte HT as showing the greatest resistance to food- and beverage-induced temperature change.

🧊Why does alternating hot and cold matter more than steady heat?

Alternating exposure forces the material and the tooth to expand and then contract repeatedly, opening and closing the marginal gap like a pump. Hammad's alternating group averaged 1.85 on the leakage scale, against 1.18 for cold alone, 1.05 for hot alone and 0.75 for uncycled controls. Under a single steady temperature, the four materials could not be reliably distinguished from one another.

⚗️What does 'smart' or bioactive dental material mean?

The label covers restoratives that are designed to react to conditions in the mouth rather than sit inertly. Activa BioACTIVE uses an ionic resin matrix with reactive glass fillers that exchange calcium, phosphate and fluoride with saliva; Cention N is an alkasite with alkaline fillers that neutralise acid; EQUIA Forte HT is a high-viscosity glass-hybrid ionomer finished with a resin surface coat. Each is marketed for ion release and marginal sealing.

📋How reliable is this kind of laboratory study?

It is useful and it is limited. The design controlled cavity size, curing time, cycling temperature and scoring, which makes the internal comparison strong. But it used sound extracted premolars, no chewing load, no saliva, no biofilm and no acid challenge, and 1,500 cycles is modest compared with protocols running 10,000 or 50,000 cycles. Dye also penetrates gaps narrower than a bacterium can pass, so dye scores tend to overstate clinical risk.

🔁Do other studies agree with these rankings?

Partly. A thermocycling study in the International Dental Journal found EQUIA Forte ahead of Activa BioACTIVE and Cention N after 5,000 cycles. A 2026 micro-CT study in Scientific Reports found EQUIA Forte HT's seal deteriorated over five years of simulated ageing while Cention N and Activa BioACTIVE held steady — but that study also found the bioactive resins equivalent to its conventional composite control, which contradicts Hammad's finding that the nanohybrid did worst.

🪥What is a Class V cavity and why was it used?

A Class V cavity is a wedge-shaped lesion on the smooth surface of a tooth near the gum line, often caused by abrasion, erosion or root caries. It is a demanding site for adhesion because the gingival margin sits in dentine or cementum rather than enamel. Hammad's cavities were cut to 4 millimetres wide, 2 millimetres tall and 2 millimetres deep, with the occlusal margin in enamel — a realistic mix of the two substrates.

☕Does this study mean patients should avoid hot or cold drinks?

No. The exposure simulated ordinary eating and drinking, not an extreme behaviour, and the authors frame temperature change as an unavoidable feature of having a restoration. The practical message is about material selection and monitoring rather than avoidance: margins should be checked at recall, because leakage progresses underneath a filling without visible warning.

📈What follow-up research does the paper call for?

Hammad and colleagues ask for further studies on the effects of food and beverage temperature change alongside other clinical conditions, so the long-term behaviour of these restoratives can be assessed more realistically. Adding chewing load to temperature cycling, testing caries-affected dentine, and measuring ion release at the same time as leakage would let researchers test the proposed mechanism rather than infer it from dye scores.

🏛️Who conducted the research and where was it published?

The study was led by Dr Hina Hammad, BDS FCPS, Assistant Professor of Operative Dentistry at Hamdard University Dental Hospital in Karachi, with Syeda Farhat Bukhari, Rabiya Nadeem, Muhammad Muslim Khahro, Muhammad Siddique Qazi and Shah Faisal. It appeared in the Indo-American Journal of Life Sciences and Biotechnology, volume 23, issue 3, pages 25 to 38, in 2026.